Transcript
AGS One 178/179 Cannon Workshops, Cannon Drive, Hertsmere
Road, London E14 4AS Customer HENDON CENTRAL LUL STATION (ABM) ABM Helpdesk ABM Helpdesk Assisted by Address Central Circus Job type ABM - LUL Pest Control - Fault NW4 3AS Reference PC/ABM/F/00284 Order number 56114085 Date 11/03/2024 03:00 - 04:00 Notes Pigeon cull required - Pigeons gather on ledges on paid side of Gateline
AGS
ONE
Resource
Contact
London
Billing address ABM UK
World Business Centre 3, Newall
Job duration
01:0:0
Koad London Heathrow Airport
Univing duration
TW6 2TA
Distance travelled
Omi
Hounslow
AGS - Pre-shoot Checklist
Answer Notes Location: Hendon central
Fault! Contract Number:
Technician Carrying Out
Shoot:
Second Person:
Have The Police Been
Yes
Notified?
CAD Number
1103202401
BigShange
We are ONE for a reason!
| Fault! Contract Number: | | |---|---| | Technician Carrying Out | | | Shoot: | | | Second Person: | | | Have The Police Been | Yes | | Notified? CAD Number | 1103202401 |
| CAD Number | 1103202401 | |---|---|
AGS One
178/179 Cannon Workshops, Cannon Drive, Hertsmere Road, London
AGS
ONE
E144AS
Has the customer and any
Yes
other contractors/people on
site not involved in the shoot,
been excluded from the area
where shoot is taking place?
Do all participating staff
Yes
understand the procedures
for the proposed shoot and
have the appropriate PPE and
paperwork to complete the
work?
Can the shoot be done safely
Yes
without affecting or being
affected by, other site
activities, neighbouring sites,
buildings, other premises,
houses, open areas and
public spaces?
Before refilling the reservoir No
on compressed air powered
air rifles, have you completed
a pre-use visual check on the
oxygen refill cylinder?
Can the shoot be done
Yes
without endangering non-target animal, protected
species (e.g. bats), livestock,
other wildlife, trees and
vegetation?
Have arrangements been
Yes
made for the proper disposal
of pest bird bodies?
Are the weather and fighting
Yes
conditions safe for the shoot
to proceed?
Shoot to proceed?
Yes
Name of Lead Tech
Lead Tech Signature
Name of SS/ DDM or Managed
Signed by SS/ DDM or
Manager
BigShange
We are ONE for a reason!
AGS One 178/179 Cannon Workshops, Cannon Drive, Hertsmere Road, London E144AS
AGS
ONE
AGS/MITIE POWRA
Answer Notes
Do you have an in date first Yes aid kit and eye wash on site?
Are you moving any No equipment or materials using a lift or escalator?
Have you read and Yes understood the Risk Assessment and Method Statement for these works, and can the works be completed safely in accordance with them?
Identify how you will be Signs securing your work site
Are all team operatives Yes trained and certified for the tasks they are undertaking?
Are all team members Yes wearing the correct PPE in line with the method statement for the tasks they will be undertaking?
Will any of the following be None affected by the works?
if required, do you have in Yes date, correctly calibrated and tested equipment for the task?
Does the task require youto No have a spill kit on site?
Is there any aspect of these No works that will bring you or the team into contact with asbestos containing material?
Does the task involve working No at height (including working on stairs, landings, and over open access chambers)?
We are ONE for a reason!
BigShange tool such as drill that require
acceptable
additional
any
part any
(including
any
| | AGS One | |---|---| | | 178/179 Cannon Workshops, Cannon Drive, Hertsmere | | | Road, | | | London | | | E14 4AS | | Will you be using a power | No | | a HAVS assessment? | | | Have all hazards been | Yes | | removed to an | | | level at this site to allow | | | works to safely continue? | | | Do you require any resources to protect the | No | | environment at this site? | | | Will the noise created by of the works affect | No | | site personnel, other | | | contractors, client staff or | | | members of the public | | | the stations | | | neighbours)? | | | Are there additional | No | | comments or notes about | | | these works? | | | Pest Control - Report | | | | Answer Notes | | Photo 1 | | | | We are ONE for a reason! |
AGS One
178/179 Cannon Workshops, Cannon Drive, Hertsmere Road, London
AGS
ONE
E14 4AS
Photo 2
Photo 3
Photo 4
BigChange
We are ONE for a reason!
Report: platform
pigeons
| | AGS One | |---|---| | | 178/179 Cannon Workshops, Cannon Drive, Hertsmere | | | Road, | | | London | | | E14 4AS | | Photo 5 | | | Pest Species Active | Feral pigeon (Columba livia) | | Location | External,Internal | | Level of Activity | Low | | Work | Cull on could not be | | | carried out safely as area | | | where were there | | | were workers on the track | | | One pigeon was culled behind | | | ticket barrier nest and dead | | | pigeon was removed from site | | Recommendations | | | (Environmental/ Housekeeping/ | | | Recommendations Proofing/ Structural) | Spiking to carried out on top of trunking | | Post Work Photo 1 | | | | We are ONE for a reason! |
Hygiene)
(Fabric/
This transcript was generated automatically and may contain errors. Refer to the original document for the exact wording.